Catheter Cardiovasc Interv ; 103(6): 909-916, 2024 May.
Article in English | MEDLINE | ID: mdl-38584525

ABSTRACT

BACKGROUND: Utilization of right ventricular mechanical circulatory support (RV-MCS) devices has been limited by a lack of recognition of RV failure as well as a lack of availability and experience with RV-MCS. AIMS: We report a single-center experience with the use of percutaneous RV-MCS and report predictors of adverse outcomes. METHODS: This was a single-center retrospective cohort study. Data from consecutive patients who received RV-MCS for any indication between June 2015 and January 2022 were included. Data on baseline comorbidities, hemodynamics, and laboratory values were collected. The primary outcome was in-hospital mortality analyzed as a logistic outcome in a multivariable model. These variables were further ranked by their predictive value. RESULTS: Among 58 consecutive patients enrolled, the median age was 66 years, 31% were female and 53% were white. The majority of the patients (48%) were hospitalized for acute on chronic heart failure. The majority of the patients were SCAI SHOCK Stage D (67%) and 34 (64%) patients had MCS placed within 24 h of the onset of shock. Before placement of RV-MCS, median central venous pressure (CVP) and RV stroke work index were 20 mmHg and 8.9 g m/m2, respectively. Median serum lactate was 3.5 (1.6, 6.2) mmol/L. Impella RP was implanted in 50% and ProtekDuo in the remaining 50%. Left ventricular MCS was concomitantly used in 66% of patients. Twenty-eight patients (48.3%) died. In these patients, median serum lactate was significantly higher (4.1 [2.3, 13.0] vs. 2.2 [1.4, 4.0] mmol/L, p = 0.007) and a trend toward higher median CVP (24 [18, 31] vs. 19 [14, 24] mmHg, p = 0.052). In the multivariable logistic model, both serum lactate and CVP before RV-MCS placement were independent predictors of in-hospital mortality. Serum lactate had the highest predictive value. CONCLUSION: In our real-world cohort, 52% of patients treated with RV-MCS survived their index hospitalization. Serum lactate at presentation and CVP were the strongest predictors of in-hospital mortality.


Subject(s)
Heart Failure , Heart-Assist Devices , Hospital Mortality , Recovery of Function , Ventricular Dysfunction, Right , Ventricular Function, Right , Humans , Female , Male , Retrospective Studies , Aged , Heart Failure/physiopathology , Heart Failure/mortality , Heart Failure/therapy , Heart Failure/diagnosis , Treatment Outcome , Middle Aged , Risk Factors , Time Factors , Ventricular Dysfunction, Right/physiopathology , Ventricular Dysfunction, Right/mortality , Ventricular Dysfunction, Right/etiology , Ventricular Dysfunction, Right/therapy , Ventricular Dysfunction, Right/diagnostic imaging , Risk Assessment , Prosthesis Implantation/instrumentation , Prosthesis Implantation/adverse effects , Prosthesis Implantation/mortality , Biomarkers/blood
3.
N Engl J Med ; 390(15): 1382-1393, 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38587239

ABSTRACT

BACKGROUND: The effects of temporary mechanical circulatory support with a microaxial flow pump on mortality among patients with ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock remains unclear. METHODS: In an international, multicenter, randomized trial, we assigned patients with STEMI and cardiogenic shock to receive a microaxial flow pump (Impella CP) plus standard care or standard care alone. The primary end point was death from any cause at 180 days. A composite safety end point was severe bleeding, limb ischemia, hemolysis, device failure, or worsening aortic regurgitation. RESULTS: A total of 360 patients underwent randomization, of whom 355 were included in the final analysis (179 in the microaxial-flow-pump group and 176 in the standard-care group). The median age of the patients was 67 years, and 79.2% were men. Death from any cause occurred in 82 of 179 patients (45.8%) in the microaxial-flow-pump group and in 103 of 176 patients (58.5%) in the standard-care group (hazard ratio, 0.74; 95% confidence interval [CI], 0.55 to 0.99; P = 0.04). A composite safety end-point event occurred in 43 patients (24.0%) in the microaxial-flow-pump group and in 11 (6.2%) in the standard-care group (relative risk, 4.74; 95% CI, 2.36 to 9.55). Renal-replacement therapy was administered to 75 patients (41.9%) in the microaxial-flow-pump group and to 47 patients (26.7%) in the standard-care group (relative risk, 1.98; 95% CI, 1.27 to 3.09). CONCLUSIONS: The routine use of a microaxial flow pump with standard care in the treatment of patients with STEMI-related cardiogenic shock led to a lower risk of death from any cause at 180 days than standard care alone. The incidence of a composite of adverse events was higher with the use of the microaxial flow pump. (Funded by the Danish Heart Foundation and Abiomed; DanGer Shock ClinicalTrials.gov number, NCT01633502.).


Subject(s)
Heart-Assist Devices , ST Elevation Myocardial Infarction , Shock, Cardiogenic , Aged , Female , Humans , Male , Heart-Assist Devices/adverse effects , Incidence , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality , Shock, Cardiogenic/surgery , ST Elevation Myocardial Infarction/complications , ST Elevation Myocardial Infarction/mortality , ST Elevation Myocardial Infarction/therapy , Treatment Outcome , Assisted Circulation/adverse effects , Assisted Circulation/instrumentation , Assisted Circulation/methods
5.
Clin Transplant ; 38(4): e15317, 2024 04.
Article in English | MEDLINE | ID: mdl-38607287

ABSTRACT

BACKGROUND: United Network for Organ Sharing (UNOS) allocation criteria changed in 2018 to accommodate the increased prevalence of patients on a ventricular assist device as a bridge to heart transplant and prioritize sicker people in anticipation of a heart graft. We aimed to assess the impact of patient age in the new allocation policy on mortality following heart transplantation. Secondary outcomes included the effect of age ≥70 on post-transplant events, including stroke, dialysis, pacemaker, and rejection requiring treatment. METHODS: The UNOS Registry was queried to identify patients who underwent heart transplants alone in the US between 2000 and 2021. Patients were divided into groups according to their age (over 70 and under 70 years old). RESULTS: Patients aged over 70 were more likely to require dialysis during follow-up, but less likely to experience rejection requiring treatment, compared with patients aged <70. Age ≥70 in the new allocation system was a significant predictor of 1-year mortality (adjusted HR: 1.41; 95% CI: 1.05-1.91; p = .024), but its effect on 5-year mortality was not significant after adjusting for potential confounders (adjusted HR: 1.27; 95% CI:.97-1.66; p = .077). Undergoing transplantation under the new allocation policy vs the old allocation policy was not a significant predictor of mortality in patients over 70 years old. CONCLUSIONS: Age ≥70 is a significant predictor of 1-year mortality following heart transplantation, but not at 5 and 10 years; however, the new allocation does not seem to have changed the outcomes for this group of patients.


Subject(s)
Heart Transplantation , Heart-Assist Devices , Pacemaker, Artificial , Humans , Aged , Aged, 80 and over , Registries , Renal Dialysis
6.
Braz J Cardiovasc Surg ; 39(3): e20230258, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38630058

ABSTRACT

INTRODUCTION: Limited options in the end-stage treatment of heart failure have led to increased use of left ventricular assist devices. For this reason, the rate of non-cardiac surgeries in patients with left ventricular assist devices is also increasing. Our study aims to analyze surgical rate, anesthesia management, and results by reviewing our 11-year experience with patients who underwent non-cardiac surgery receiving left ventricular assist devices support. METHODS: We retrospectively evaluated 57 patients who underwent non-cardiac surgery and 67 non-cardiac surgical procedures among 274 patients who applied between January 2011 and December 2022 and underwent left ventricular assist devices implantation with end-stage heart failure. RESULTS: Fifty (74.6%) patients with left ventricular assist devices admitted to the hospital for non-cardiac surgery were emergency interventions. The most common reasons for admission were general surgery (52.2%), driveline wound revision (22.3%), and neurological surgery (14.9%). This patient group has the highest in-hospital mortality rate (12.8%) and the highest rate of neurological surgery (8.7%). While 70% of the patients who underwent neurosurgery were taken to surgery urgently, the International Normalized Ratio values of these patients were between 3.5 and 4.5 at the time of admission to the emergency department. CONCLUSION: With a perioperative multidisciplinary approach, higher morbidity and mortality risks can be reduced during emergencies and major surgical procedures.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Retrospective Studies , Hospitals , Heart Ventricles , Heart Failure/surgery
7.
Cardiol Clin ; 42(2): 187-193, 2024 May.
Article in English | MEDLINE | ID: mdl-38631789

ABSTRACT

Cardiogenic shock is a lethal condition with significant morbidity, characterized by myocardial insults leading to low cardiac output and ensuing systemic hypoperfusion. While mortality rates remain high, we have improved upon our recognition and definition of cardiogenic shock, now with an emphasis on defining stages of shock to help guide effective treatment strategies with either pharmacologic or mechanical circulatory support. In this review, the authors summarize these stages as well as discuss indications, function, selection, and troubleshooting of the various temporary mechanical circulatory support devices.


Subject(s)
Heart-Assist Devices , Shock, Cardiogenic , Humans , Shock, Cardiogenic/therapy , Treatment Outcome , Intra-Aortic Balloon Pumping
8.
J Cardiothorac Surg ; 19(1): 167, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38561765

ABSTRACT

BACKGROUND: The implantation of left ventricular assist devices (LVADs) as a bridge to transplantation or as destination therapy in end-stage heart failure patients is frequently complicated by the emergence of ventricular arrhythmias (VAs). These arrhythmias have been implicated in precipitating deleterious clinical outcomes, increased mortality rates and augmented healthcare expenditures. CASE PRESENTATION: We present a challenging case of a 49-year-old male with a history of dilated cardiomyopathy who received an LVAD. Post-implantation, the patient suffered from intractable VAs, leading to multiple rehospitalizations and hemodynamic deterioration. Despite exhaustive medical management and electrical cardioversion attempts, the patient's VAs persisted, ultimately necessitating prioritization for cardiac transplantation. DISCUSSION: This case highlights the challenges in managing VAs in LVAD patients and the importance of multidisciplinary collaboration. While pharmacological intervention is the initial strategy, catheter ablation may be considered in selected cases when medication is insufficient. In instances of intractable VAs, expeditious listing for heart transplantation as a high-priority candidate is advisable when feasible.


Subject(s)
Heart Failure , Heart-Assist Devices , Male , Humans , Middle Aged , Heart-Assist Devices/adverse effects , Heart Failure/complications , Heart Failure/surgery , Arrhythmias, Cardiac/etiology , Hemodynamics , Electric Countershock , Treatment Outcome
9.
Eur Rev Med Pharmacol Sci ; 28(6): 2199-2206, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38567583

ABSTRACT

OBJECTIVE: Pediatric heart failure is an important cause of morbidity and mortality in childhood. Left ventricular assist devices (L-VAD) are used for bridging to transplantation in patients with indications for heart transplantation. PATIENTS AND METHODS: The children included in the study were patients who underwent implantation of an L-VAD due to advanced heart failure at Ege University Faculty of Medicine Hospital between January 2009 and January 2023. RESULTS: Of the 33 patients who underwent L-VAD implantation, 16 (48.5%) were female and 17 (51.5%) were male. The median age at surgery was 13 years (IQR, 9.5-15). The median weight was 44 kg (IQR, 25.65-52), the median height was 158 cm (IQR, 134.5-168.5), and the median body surface area was 1.37 m2 (IQR, 0.95-1.51). All patients who underwent L-VAD implantation had an echocardiographic diagnosis of dilated cardiomyopathy. The patients underwent a median of 16 (IQR, 9-21) ECGs, and the median number of 24-hour Holter ECGs obtained was 3 (IQR, 2-5). Arrhythmias that occurred after L-VAD implantation were classified as atrial and ventricular. Ventricular arrhythmia included ventricular tachycardia (VT) lasting for more than 30 seconds (sustained VT), VT lasting for less than 30 seconds (nonsustained VT), and ventricular fibrillation. Atrial arrhythmias included atrial flutter, atrial fibrillation, supraventricular tachycardia, and atrial ectopic tachycardia. During the follow-up, atrial or ventricular arrhythmias were observed in 11 (33%) patients. The most common rhythm disturbances before L-VAD implantation were ventricular arrhythmias, while after the surgery, atrial arrhythmias were found to be the most frequent. A total of 5 patients underwent cardioversion (n=2) or defibrillation (n=3) due to arrhythmia. CONCLUSIONS: In patients undergoing L-VAD implantation, rhythm disorders that could normally lead to hemodynamic instability are frequently encountered. In these rhythm disorders, medical therapy should be attempted before resorting to cardioversion or defibrillation, and subsequently, more aggressive treatment methods should be considered.


Subject(s)
Atrial Fibrillation , Heart Failure , Heart-Assist Devices , Tachycardia, Supraventricular , Tachycardia, Ventricular , Humans , Male , Female , Child , Adolescent , Heart-Assist Devices/adverse effects , Heart Failure/therapy , Heart Failure/complications
10.
Ann Plast Surg ; 92(4S Suppl 2): S200-S203, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38556673

ABSTRACT

BACKGROUND: The use of left ventricular assist devices (LVADs) for patients with end-stage cardiac failure awaiting heart transplantation has become increasingly common. However, ventricular assist device-related infections remain a major problem complicating their long-term use. Retrospective review has previously shown a decrease in lifetime return to operating room (RTOR) with no change in 90-day complications when a muscle or omental flap is used for coverage after washout for infection. We wished to determine if early plastic surgery intervention led to a decreased length of stay for these patients. METHODS: Patients with LVAD readmitted for LVAD infection at a single institution from 2008 to 2021 were identified using a preexisting database. Patients were followed retrospectively for an average of 3.2 years. Patient demographics, preoperative diagnosis/disease state, type of ventricular assist device inserted, postoperative day of ventricular assist device infection onset, definitive device coverage, timing of coverage procedure after the initial washout for infection, type of flap used for coverage, 90-day complications after definitive coverage, and lifetime return to operating room for infection were reviewed. Comparison analysis with χ2 and analysis of variance testing was used to analyze outcomes. RESULTS: Of 568 patients admitted with an LVAD infection, 104 underwent operative debridement and closure by plastic and reconstructive surgery (PRS) or cardiothoracic surgery (CTS). Fifty-three underwent PRS closure, and 51 underwent CTS closure. There was an increased incidence of diabetes among the PRS group (P < 0.001); otherwise, there was no difference in baseline characteristics. There was increased RTOR over a lifetime with CTS closure compared with PRS (P = 0.03) and increased 90-day risk of infection (P = 0.007). Patients with PRS closure had an increased risk of postoperative hematoma (P = 046). Plastic and reconstructive surgery was typically consulted on hospital day 10. Both PRS and CTS closure patients were discharged on postoperative day 7, on average (P = 0.542). CONCLUSIONS: Plastic surgery involvement with surgical decision making and closure of infected LVAD devices has a decrease in lifetime RTOR and decreased 90-day complications related to infections. There may be a benefit to earlier PRS consultation for coverage assessment.


Subject(s)
Heart Failure , Heart-Assist Devices , Prosthesis-Related Infections , Surgery, Plastic , Humans , Heart-Assist Devices/adverse effects , Retrospective Studies , Operating Rooms , Prosthesis-Related Infections/etiology , Heart Failure/surgery , Heart Failure/etiology , Treatment Outcome
11.
Perfusion ; 39(1_suppl): 13S-22S, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38651575

ABSTRACT

INTRODUCTION: Veno-arterial extracorporeal membrane oxygenation (V-A ECMO) improves end-organ perfusion in cardiogenic shock but may increase afterload, which can limit cardiac recovery. Left ventricular (LV) unloading strategies may aid cardiac recovery and prevent complications of increased afterload. However, there is no consensus on when and which unloading strategy should be used. METHODS: An online survey was distributed worldwide via the EuroELSO newsletter mailing list to describe contemporary international practice and evaluate heterogeneity in strategies for LV unloading. RESULTS: Of 192 respondents from 43 countries, 53% routinely use mechanical LV unloading, to promote ventricular recovery and/or to prevent complications. Of those that do not routinely unload, 65% cited risk of complications as the reason. The most common indications for unplanned unloading were reduced arterial line pulsatility (68%), pulmonary edema (64%) and LV dilatation (50%). An intra-aortic balloon pump was the most frequently used device for unloading followed by percutaneous left ventricular assist devices. Echocardiography was the most frequently used method to monitor the response to unloading. CONCLUSIONS: Significant variation exists with respect to international practice of ventricular unloading. Further research is required that compares the efficacy of different unloading strategies and a randomized comparison of routine mechanical unloading versus unplanned unloading.


Subject(s)
Extracorporeal Membrane Oxygenation , Humans , Extracorporeal Membrane Oxygenation/methods , Surveys and Questionnaires , Female , Male , Shock, Cardiogenic/therapy , Shock, Cardiogenic/physiopathology , Heart-Assist Devices
12.
Article in English | MEDLINE | ID: mdl-38618610

ABSTRACT

Left ventricular assist devices serve as a salvage therapy for patients with advanced heart failure. Complications such as thrombosis and obstruction can lead to acute device malfunction, posing significant clinical risks. A multidisciplinary approach is crucial for management. Few cases in the literature have demonstrated the safety and efficacy of percutaneous intervention, which holds significant value due to its less invasive nature and minimal risk of morbidity, especially in high-risk surgical patients.


Subject(s)
Heart Failure , Heart-Assist Devices , Thrombosis , Humans , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/therapy , Heart Failure/diagnosis , Heart Failure/etiology , Heart Failure/therapy
13.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38613845

ABSTRACT

OBJECTIVES: Myocardial recovery in children supported by a durable left ventricular assist device is a rare, but highly desirable outcome because it could potentially eliminate the need for a cardiac transplant and the lifelong need for immunosuppressant therapy and the risk of complications. However, experience with this specific outcome is extremely limited. METHODS: All patients < 19 years old supported by a durable left ventricular assist device from the European Registry for Patients with Mechanical Circulatory Support database were included. Participating centres were approached for additional follow-up data after explantation. Associated factors for explantation due to myocardial recovery were explored using Cox proportional hazard models. RESULTS: The incidence of recovery in children supported by a durable left ventricular assist device was 11.7% (52/445; median duration of support, 122.0 days). Multivariable analyses showed body surface area (hazard ratio 0.229; confidence interval 0.093-0.565; P = 0.001) and a primary diagnosis of myocarditis (hazard ratio 4.597; confidence interval 2.545-8.303; P < 0.001) to be associated with recovery. Left ventricular end-diastolic diameter in children with myocarditis was not associated with recovery. Follow-up after recovery was obtained for 46 patients (88.5%). Sustained myocardial recovery was reported in 33/46 (71.7%) at the end of the follow-up period (28/33; >2 year). Transplants were performed in 6/46 (11.4%) (in 5 after a ventricular assist device was reimplanted). Death occurred in 7/46 (15.2%). CONCLUSIONS: Myocardial recovery occurs in a substantial portion of paediatric patients supported with durable left ventricular assist devices, and sustainable recovery is seen in around three-quarters of them. Even children with severely dilated ventricles due to myocarditis can show recovery. Clinicians should be attentive to (developing) myocardial recovery. These results can be used to develop internationally approved paediatric weaning guidelines.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Myocarditis , Humans , Child , Young Adult , Adult , Heart-Assist Devices/adverse effects , Myocarditis/surgery , Myocardium , Diastole , Heart Failure/surgery , Treatment Outcome
14.
Heart Fail Clin ; 20(2): 155-165, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38462320

ABSTRACT

Heart failure has become the leading cause of mortality in adult congenital heart disease (ACHD) patients after the fifth decade of life. There is scanty evidence supporting the use of guideline-directed medical therapy in ACHD, especially in systemic right ventricle or single ventricle physiology. In complex patients, diagnosing heart failure and timely referral for advanced therapies are challenging. Mechanical circulatory support has been significantly developed over the past decade and has recently emerged as a feasible therapeutic option for these patients. This review summarizes current evidence of mechanical circulatory support in this population, its potential uses, and challenges.


Subject(s)
Heart Defects, Congenital , Heart Failure , Heart-Assist Devices , Humans , Adult , Heart Defects, Congenital/complications , Heart Defects, Congenital/therapy , Heart Defects, Congenital/diagnosis , Heart-Assist Devices/adverse effects , Heart Failure/diagnosis , Heart Ventricles
15.
Interv Cardiol Clin ; 13(2): 191-205, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38432762

ABSTRACT

Mitral regurgitation complicated by cardiogenic shock creates a unique and devastating risk profile for patients and poses significant difficulties for physicians who lack a comprehensive range of effective management strategies. Supportive measures such as intravenous vasodilators, intra-aortic balloon pumps, and percutaneous ventricular assist devices are often necessary to stabilize patients prior to definitive treatment with surgical mitral valve replacement or trans-catheter edge-to-edge repair. This review evaluates the evidence for the available supportive and definitive management strategies in patients with mitral regurgitation complicated by cardiogenic shock and presents a framework to aid clinicians in navigating the complex clinical decision-making process. Additionally, the authors review emerging transcatheter mitral valve replacement technologies that hold promise for expanding the therapeutic armamentarium and improving patient outcomes.


Subject(s)
Heart-Assist Devices , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/surgery , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Clinical Decision-Making , Risk Assessment
19.
Int J Artif Organs ; 47(4): 303-308, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38520143

ABSTRACT

With the general population aging, both life expectancy and the number of left ventricular assist device (LVAD) implantations in elderly patients are growing. Nevertheless, their perceived long-term quality of life, including psychological aspects, coupled with the respective caregiver's burden, remain under-reported. In light of the rising number of octogenarians with LVAD who necessitate broader healthcare provider involvement, we assessed the long-term quality of life, as defined by both the 36-item short-form health (SF-36) survey and the EuroQol 5 dimensions, 5-level questionnaire (EQ-5D-5L)-including the visual analog scale-in octogenarian LVAD patients who had received treatment at our institution. Additionally, we evaluated the psychological health of octogenarian LVAD patients using the psychological general well-being index (PGWBI), alongside their caregivers' well-being through the 22-item version of the Zarit Burden Interview (ZBI). Of 12 octogenarian LVAD patients, 5 were alive and willing to answer questionnaires. Mean age at implant was 74 ± 2 years. Median follow-up was 2464 (IQR = 2375-2745) days. Although variable, the degree of health and psychological well-being perceived by octogenarian patients with LVAD was "good." Interestingly, the burden of assistance reported by caregivers, though relevant, was greatly varied, suggesting the need to better define and address psychological long-term aspects related to LVAD implantation for both patients and caregivers with a broad-spectrum approach.


Subject(s)
Caregiver Burden , Heart-Assist Devices , Quality of Life , Humans , Heart-Assist Devices/psychology , Male , Female , Caregiver Burden/psychology , Aged , Aged, 80 and over , Psychological Distress , Surveys and Questionnaires , Heart Failure/psychology , Heart Failure/surgery , Heart Failure/therapy , Caregivers/psychology
20.
Catheter Cardiovasc Interv ; 103(5): 799-802, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38461378

ABSTRACT

Ramp studies are utilized for speed optimization of continuous flow left ventricular assist devices (CF-LVADs). We here report the utility of combined left and right heart catheterization during a ramp study to ensure a comprehensive understanding of the hemodynamic implications on both ventricles. Pressure-volume loop (PV loop) monitoring uncovered compromised systolic and mildly compromised right ventricular function with increasing LVAD speeds, despite improvement in left ventricular unloading. These findings informed patient management and highlight the potential utility of PV loop monitoring as an adjunct to left and right heart catheterization during ramp studies of next-generation LVADs.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Ventricular Function, Right , Treatment Outcome , Hemodynamics , Cardiac Catheterization , Heart Failure/diagnosis , Heart Failure/therapy , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...